Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (25)
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
  • Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
LW36-126/3150-40
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Transport Package
Wooden Crate or Cardboard Box
Specification
customizable
Trademark
NCEA
Origin
China
HS Code
3101
Production Capacity
500 Units/Week

Packaging & Delivery

Package Size
50.00cm * 800.00cm * 1000.00cm
Package Gross Weight
500.000kg
Lead Time
7 days (1 - 5 Pieces)
15 days (6 - 15 Pieces)
To be negotiated ( > 15 Pieces)

Product Description

Summary
The LW36-145/3150-40 self powered AC high-voltage sulfur hexafluoride circuit breaker is an outdoor product suitable for use in AC 50HB power grids with a maximum voltage of 145kV in areas with an altitude not exceeding 3000 meters, an ambient temperature not lower than -40P, and a pollution level not higher than IV. It is used to cut off rated current, fault current, or conversion lines, achieve control and protection of the power system, and can also be used as a contact circuit breaker
This product uses SF6 gas as the arc extinguishing and insulation medium, adopts the most advanced self energy arc extinguishing technology in the world, and is equipped with a new type of spring operating mechanism. It has the characteristics of long electrical life, low operating power, low noise, and high reliability. Its structure is simple, small in size, and long without maintenance cycle. It is the most reliable product in high-altitude areas or 132kV power systems, and can replace imported products of the same type


Structural characteristics
The circuit breaker adopts a three-phase ceramic pillar single break structure, with a spring operated mechanism for the three phases. It is centrally arranged and interconnected with the three phases, resulting in a novel and exquisite appearance The circuit breaker uses SF6 gas as the insulation and arc extinguishing medium. During operation, the three poles of the circuit breaker are connected to SF6 gas, and a pointer type density relay is used to monitor its pressure and density progress Due to the use of self powered arc extinguishing principle and optimized design in the circuit breaker motion system, the mechanical efficiency has been effectively improved and the operating power has been minimized to the greatest extent possible;
Excellent breaking performance and long electrical lifespan;
The installation chassis and support are made of high-quality steel plates that are bent as a whole, and the surface treatment is all hot-dip galvanized. All exposed fasteners are made of high-strength materials and hot-dip galvanized, or use stainless steel standard parts. The outer shell of the mechanism box is made of stainless steel material, so the product has excellent corrosion resistance;
High mechanical reliability, capable of frequent operation;
Due to the inherent high insulation strength of sulfur hexafluoride gas and the use of optimal contact movement in circuit breakers, there is no reignition of capacitive current during circuit breaker breaking;
The external insulation level is high, and the external insulation is designed with a large creepage distance. The creepage distance is N31mm/kV, and the anti pollution performance is excellent Can operate safely even in harsh environments;
Strong current carrying capacity: Conduct a temperature rise test at 1.2 times the rated current of 3150A, which is 3780A1s, and there is still a large margin for temperature rise at each point;
The overall appearance structure of the product is compact, easy to install and debug on site, and the maintenance workload is small
Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
Outdoor Support Customized Communication Sulfur Hexafluoride Circuit Breaker MCB Circuit Breaker
 
technical parameter
Main technical parameters of circuit breaker
Table 1
serial number
1

1
Name: Rated Voltage unit
kV

 
parameter 
LW36-126KV
2 Insulation level kV See Table 2.
  rated current Hz 50
4 Rated current A 3150
5 rated current kA 40
6 Rated short-time withstand current kA 40
7 Rated peak withstand current kA 100
8 rated short-circuit duration s 3
9 Rated short-circuit closing current (peak) kA 100
10 Short-line fault breaking current kA 36/30
11 Rated line charging breaking current A 31.5
12 Rated out-of-step breaking current kA 10
13 Cumulative number of interruptions under rated short-circuit breaking current times 20
14 first pole opening factor   1.5
15 SF6 gas pressure (20 ° C) MPa 0.5
16 Rated voltage of power supply for control circuit and auxiliary circuit   DC220V DC110V
17 rated operation sequence   points-0.3s-combined points-180s-combined points
18 mechanical characteristics   See Table 5.
  Rated main circuit resistance M Q W55
20 Circuit breaker mechanical durability times 10000
  Horizontal and vertical FshA N 1250
21 Terminal block static tension, horizontal horizontal FshB N 750
  Vertical direction FtVm N 1000
22 SF6Annual gas leakage rate % W1
23 SF6Gas moisture content (V/V) ppm w150±4
24 Contact travel mm 150 + 4
25 Contact contact travel mm 25




 
Order Instructions
Circuit breaker model, specification;
Rated electrical parameters (voltage, current, breaking current, etc.)
Use environmental conditions (ambient temperature, altitude, environmental pollution level)
Rated control circuit electrical parameters (energy storage motor rated voltage, opening coil rated voltage);
The name and quantity of spare parts, special equipment and tools required (to be ordered separately); the wiring direction of the terminal at one time.


FAQ

Q: Are you a factory or a trading company?

A: We are a factory with a 10 year production and sales history in AC/DC power supply, uninterruptible power supply. We warmly welcome your visit.

Q: What is the delivery time?
A: Generally, the delivery time is between 7-30 days after receiving payment from the customer.
Accurate information depends on the product and quantity, and we can further communicate on this.

Q: Do you have a minimum order quantity requirement?
A: The minimum order quantity for most products is 1 set. The minimum order quantity for individual UPS is 10

Q: How long is your warranty period?
A: We provide customers with a 2-year warranty and a 1-year warranty.

Q: Can you provide customized services?
A: Yes. Since 20014, we have been involved in OEM and ODM projects.
So that we can provide professional customized services for our customers.

Q: Do you have after-sales service?

A: Yes, we have an after-sales service team.
Our after-sales engineers can provide support and guidance through video or phone when needed.

Q: Do you conduct testing after completing production?
A: Yes, our production engineer team will conduct testing upon completion of the goods, and we will provide the testing information to customers for reference before delivery.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier