Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets

Product Details
Customization: Available
Phase: Single Phase
Type: On-line
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (25)
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
  • Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets
Find Similar Products

Basic Info.

Model NO.
UPS
Protection
Unbalanced Loads
Application
Fire Safety
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Small Type
Equipment Mode
Decentralized
Brand
Xinsilu
Transport Package
Crate
Specification
282*145*220
Trademark
NICEA
Origin
China
HS Code
3101
Production Capacity
500pieces/Week

Product Description

7. Storage and maintenance
7-1. Storage
Please charge for 7 hours before storing this product. Store it upright in a dry place.
During storage, please perform charg ing maintenance according to the following table:

 
Storage temperature Charging interval Cha rging time
-25°C - 40°C Every 3 months 1 to 2 hours
40°C - 45°C Every 2 months 1 to 2 hours

7-2. Maintenance

Th e U PS system uses dan g ero us voltage and can onI y be repaired by qualified maintenance personnel .

There is a danger of electric shock. Even if the main power supply is disconnected, the components in the UPS system are still connected to the battery and are dang erous.

To perform any service or maintenance, you should disconnect the battery first and confirm that there is no dangerous voltage across the bus capacitor.

Only maintenance personnel who are fully familiar with batteries and have prepared protective measures can engage in or supervise battery replacement operations. Unauthorized personnel must stay away from the battery.

There is a risk of electric shock. The battery circuit is not isolated from the mains input. Dangerous voltage may appear between the battery terminal and the ground. Before touching, please make sure there is no voltage!

The battery may cause electric shock and generate short-circuit high current. Before repairing, please remove metal objects such as watches and rings, and use tools with insulator handles and handles during repairs.

When replacing batteries, please install batteries of the same number and specifications.

Do not throw the battery into the fire, otherwise it may cause an explosion. Waste batteries should be disposed of in accordance with local regulations.

Do not disassemble or damage the battery. Once the electrolyte contained in the battery leaks, it will cause damage to the skin and eyes, and may even be toxic.
OnIy replace fuses of the same type and amperage to avoid fire. Non-professionals should not disassemble the UPS system.
Model Wall-mounted type Vertical type
6KVA 10KVA 6KVA 1OKVA
Capacity 6KW 10KW 6KW 10KW
In put

Voltage Range
Minimum switching voltage At 50% load, 11OVAC z3%; at 100% load, 176VAC13%
Minimum recovery voltage Minimum switching voltage +10V
Maximum switching voltage 300VAC*3 %
Maximum recovery voltage Maximum switching voltage -10V
Frequency Range 40-60HZ@50HZ system/50-70HZ@60HZ system
Phase L+ N+PE
Power Factor 100% load*0.99
Output
Output Voltage 208/220/230/240VAC
Output Voltage Accuracy *1%
Frequency Range (synchronization range) 40-60hz@50HZsystemI50-70HZ@60HZsystem
Frequency Range (battery mode) 50hz*0.1HZor60HZ*0.1HZ

Overload
AC Mode 30min@102%-110%Ioad, 10min@110%-130%load 30s@130%-150%Ioad, 500ms@ >150%Ioad
Battery Mode 10min@102%-110%Ioad, 1min@110%-130%Ioad 10s@130%-150%Ioad, 500ms@ >150%Ioad
Current peak ratio 3:1 (Maximum)
Harmonic distortion S2% ( linear load ) , 5%(non-linear load)
Switching time Mains Battery Oms
Inverter Bypass Oms
Effectiveness
AC Mode 95%
Battery Mode 94.8% (20pcs batteries)
Battery

Standard
Battery Number 12-16 pcs 16 pcs 12-16 pcs 16 pcs
Charging Current default 1A
Charging Voltage 13.65 x NI-1%

Long Run
Battery Number 16 -20 pcs
Charging Current Preset: 6A-L 10%, 1-12A optional
Charging Voltage 13.65 x N+1%
Apperance
Standard Size Long•Width•High(mm) 380*438*88
(Battery pack size: 496a438 130)
384"190*730
Long Run Size
Long Width High(mm)
380"438*88 384"190*335
Environment
Operating Temperature 0 - 40°C
Operating Moisture < 95% And no condensation
Operating Altitude < 1000m"*
Noise less than 50dB@1 Meter
Management
Sm artRS-232 Support Windows@2000/2003/XP/Vista/2008. Windows@7/8. Linux. Unix and MAC
0 ptional SNMP Support for power management by SNMP administrator and web browser.
Tech nical parameters
 
Model Wall-mounted type Vertical type
1KVA 2KVA 3KVA 1KVA 2KVA 3KVA
Capacity 1KW 2KW 3KW 1KW 2KW 3KW
Input

Voltage
Range
Minimum switching voltage At 50% load, 11OVAC +3%; at 100% load, 176VAC+3 %
Minimum recovery voltage Minimum switching voltage +10V
Maximum switching voltage 300VACI3 %
Maximum recovery voltage Maximum switching voltage -10V
Frequency Range 40-60HZ@50HZ system/50-70HZ@60HZ system
Phase L+ N+PE
Power Factor 100% load z0.99
Output
Output Voltage 208/220/230/240VAC
Output Voltage Accuracy I1%
Frequency Range
(synchronization range)
40-60hz@50HZsystem/50-70HZ@60HZsystem
Frequency Range (battery mode) 50hz+0.1 HZor60HZ+0.1 HZ

Overload
AC Mode 30min@102%-110%Ioad, 10min@110%-130%load 30s@130%-150%Ioad, 500ms@>150 %Ioad
Battery Mode 10min@102%-110%Ioad, 1min@110%-130%load 10s@130%-150%Ioad, 500ms@> 150 %Ioad
Current peak ratio 3:1 (Maximum)
Harmonic distortion 2% ( linear load ) , 5%(non-linear load)
Switching time Mains  Battery Oms
Inverter Bypass 0ms
Effectiveness
AC Mode 95%
Battery Mode 94.8% (20pcs batteries)
Battery

Standard
Battery Number 2 pcs 4 pcs 6 pcs 2 pcs 4 pcs 6 pcs
Charging Current default 1A
Charging Voltage 13.65 x NI1 %

Long Run
Battery Number 3 pcs 6 pcs 8 pcs 3 pcs 6 pcs 8 pcs
Charging Current Preset: 6A110%, 1-12A optional
Charging Voltage 13.65x N*1%
Apperance
Standard Size
Long Width High(mm)
310"438"88 380"438"88 506"438"88 284"145"213 398"145"213 450"192"335
Long Run Size
Long Width High(mm)
310"438"88 380"438"88 380"438"88 284"145"213 398"145"213 398"145"213
Environment
Operating Temperature 0-40°C
Operating Moisture < 95%And no condensation
Operating Altitude < 1000m""
Noise less than 50dB@1Meter
Management
SmartRS-232 Suppon Windows@2000/2003/XP/Vista/2008. Windows@7/8, Linux. Unix and MAC
Optional SNMP Support for power management by SNMP administrator and web browser.
"When the output voltage is set to 208VAC, the output power will be reduced to 90%.
"*If the UPS is installed and used in an environment with an altitude of more than 1000 meters, the output power should be calculated to decelerate by 1% per 100 meters.
"""Please understand that there will be no notice when product specifications are changed.
Rack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC OutletsRack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC OutletsRack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC OutletsRack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC OutletsRack Tower Convertiable Online UPS 1kVA - 10kVA with PF1 Output and 8PCS IEC Outlets


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now